Renesas Electronics /R7FA2E1A9 /CTSU /CTSUCALIB

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as CTSUCALIB

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (0)TSOD 0 (0)DRV 0 (00)CLKSEL 0 (0)SUCLKEN 0 (0)TSOC 0 (0)CNTRDSEL 0 (0)IOC 0 (0)CFCRDMD 0 (0)DCOFF 0CFCSEL0 (0)CFCMODE 0 (0)DACMSEL 0 (0)DACCARRY 0 (0)SUMSEL 0 (0)SUCARRY 0 (0)DACCLK 0 (0)CCOCLK 0 (0)CCOCALIB 0 (0)TXREV

TXREV=0, DACCARRY=0, CLKSEL=00, CCOCLK=0, CNTRDSEL=0, CCOCALIB=0, CFCRDMD=0, DACCLK=0, SUCLKEN=0, TSOD=0, IOC=0, SUCARRY=0, SUMSEL=0, DACMSEL=0, DCOFF=0, CFCMODE=0, TSOC=0, DRV=0

Description

CTSU Calibration Register

Fields

TSOD

TS Pin Fixed Output

0 (0): Capacitance measurement mode

1 (1): Output high or low from TS terminals (controlling by the IOC bit)

DRV

Power Supply Calibration Select

0 (0): Capacitance measurement mode

1 (1): Power supply calibration mode

CLKSEL

Observation Clock Select

0 (00): Not selected (L fixed output)

1 (01): Measurement clock (divided by 8)

2 (10): CFC clock (divided by 8)

3 (11): SUCLK (divided by 8)

SUCLKEN

SUCLK Forced Oscillation Control

0 (0): SUCLK oscillation only during measurement

1 (1): SUCLK always oscillates

TSOC

Switched Capacitor Operation Calibration Select Bit

0 (0): Capacitance measurement mode

1 (1): Switched capacitor operation calibration mode

CNTRDSEL

Read Count Select of Sensor Counter

0 (0): Read once

1 (1): Read twice

IOC

TS Pin Fixed Output Value Set

0 (0): Low level

1 (1): High level

CFCRDMD

CFC Counter Read Mode Select

0 (0): Except for mutual capacitance parallel measurement mode

1 (1): Mutual capacitance parallel measurement mode

DCOFF

Down Converter Control

0 (0): Voltage down converter operation (TSCAP voltage generation)

1 (1): The voltage down converter is off

CFCSEL

Observation CFC Clock Select

CFCMODE

CFC Oscillator Calibration Mode Select

0 (0): CFC current measurement (Capacitance measurement mode)

1 (1): External current measurement for calibration

DACMSEL

Current Offset DAC Current Matrix Calibration Select

0 (0): Capacitance measurement mode

1 (1): Current offset DAC current Calibration mode

DACCARRY

Offset Current Adjustment for Calibration

0 (0): Normal operation

1 (1): All current sources can be turned on

SUMSEL

Current Control Oscillator Input Current Matrix Calibration Select

0 (0): Capacitance measurement mode

1 (1): Current control oscillator input current matrix calibration mode

SUCARRY

Current Control Oscillator Input Current Adjustment for SUCLK

0 (0): Normal operation

1 (1): All current sources can be turned on

DACCLK

Modulation Clock Select for Offset Current Circuits

0 (0): Operating clock selected by CTSUCRA.CLK [1:0]

1 (1): SUCLK

CCOCLK

Modulation Clock Select for Current Controlled Oscillator Input Current of SUCLK

0 (0): Operating clock selected by CTSUCRA.CLK [1:0]

1 (1): SUCLK

CCOCALIB

Calibration Selection of Current Controlled Oscillator for Measurement

0 (0): Capacitance measurement mode

1 (1): Oscillator calibration mode

TXREV

Transmit Pin Inverted Output

0 (0): Normal

1 (1): Invert

Links

() ()